Water-wall & Superheater Tube in Power Boiler
Observation : External wastage beneath adherent slag deposit
Cause : Corrosion from Slag Attack
Remarks : Molten ash creates corrosive sulfur species. Alkali sulfates are formed where metal temperatures are greater than 1000°F and pyrosulfates where temperatures are greater than 700°F.